Commit 51d37f0f authored by suhuiguang's avatar suhuiguang

1.技术参数调整新增字段

parent 66f4b62f
...@@ -186,5 +186,12 @@ public class EquipTechParamBoiler extends AbstractEquipBaseEntity { ...@@ -186,5 +186,12 @@ public class EquipTechParamBoiler extends AbstractEquipBaseEntity {
@TableField(value ="\"GL_AIRTIGHT_TEST\"") @TableField(value ="\"GL_AIRTIGHT_TEST\"")
private BigDecimal glAirtightTest; private BigDecimal glAirtightTest;
/**
*安装附件与有关装置
*/
@TableField(value ="\"SAFETY_ACCESSORIES_AND_RELATED_DEVICES\"")
private String safetyAccessoriesAndRelatedDevices;
} }
...@@ -2,12 +2,10 @@ package com.yeejoin.amos.boot.module.ymt.api.entity; ...@@ -2,12 +2,10 @@ package com.yeejoin.amos.boot.module.ymt.api.entity;
import com.baomidou.mybatisplus.annotation.TableField; import com.baomidou.mybatisplus.annotation.TableField;
import com.baomidou.mybatisplus.annotation.TableName; import com.baomidou.mybatisplus.annotation.TableName;
import com.yeejoin.amos.boot.biz.common.entity.BaseEntity;
import com.yeejoin.amos.boot.biz.common.entity.TzsBaseEntity; import com.yeejoin.amos.boot.biz.common.entity.TzsBaseEntity;
import lombok.Data; import lombok.Data;
import lombok.EqualsAndHashCode; import lombok.EqualsAndHashCode;
import lombok.experimental.Accessors; import lombok.experimental.Accessors;
import java.util.Date;
/** /**
* 安全追溯-锅炉 * 安全追溯-锅炉
...@@ -21,169 +19,174 @@ import java.util.Date; ...@@ -21,169 +19,174 @@ import java.util.Date;
@TableName("idx_biz_jg_tech_params_boiler") @TableName("idx_biz_jg_tech_params_boiler")
public class IdxBizJgTechParamsBoiler extends TzsBaseEntity { public class IdxBizJgTechParamsBoiler extends TzsBaseEntity {
/** /**
* *
*/ */
@TableField("\"RECORD\"") @TableField("\"RECORD\"")
private String record; private String record;
/** /**
* *
*/ */
@TableField("\"INSTANCE_ID\"") @TableField("\"INSTANCE_ID\"")
private String instanceId; private String instanceId;
/** /**
* *
*/ */
@TableField("\"STATUS\"") @TableField("\"STATUS\"")
private String status; private String status;
/** /**
* *
*/ */
@TableField("\"DEVICE_LEVEL\"") @TableField("\"DEVICE_LEVEL\"")
private String deviceLevel; private String deviceLevel;
/** /**
* *
*/ */
@TableField("\"RATED_EVAPORATION_CAPACITY_THERMAL_POWER\"") @TableField("\"RATED_EVAPORATION_CAPACITY_THERMAL_POWER\"")
private String ratedEvaporationCapacityThermalPower; private String ratedEvaporationCapacityThermalPower;
/** /**
* *
*/ */
@TableField("\"RATED_WORKING_PRESSURE\"") @TableField("\"RATED_WORKING_PRESSURE\"")
private String ratedWorkingPressure; private String ratedWorkingPressure;
/** /**
* *
*/ */
@TableField("\"RATED_OPERATING_TEMPERATURE\"") @TableField("\"RATED_OPERATING_TEMPERATURE\"")
private String ratedOperatingTemperature; private String ratedOperatingTemperature;
/** /**
* *
*/ */
@TableField("\"DESIGN_THERMAL_EFFICIENCY\"") @TableField("\"DESIGN_THERMAL_EFFICIENCY\"")
private String designThermalEfficiency; private String designThermalEfficiency;
/** /**
* *
*/ */
@TableField("\"FEEDWATER_TEMPERATURE\"") @TableField("\"FEEDWATER_TEMPERATURE\"")
private String feedwaterTemperature; private String feedwaterTemperature;
/** /**
* *
*/ */
@TableField("\"RATED_OUTLET_RETURN_WATER_OIL_TEMPERATURE\"") @TableField("\"RATED_OUTLET_RETURN_WATER_OIL_TEMPERATURE\"")
private String ratedOutletReturnWaterOilTemperature; private String ratedOutletReturnWaterOilTemperature;
/** /**
* *
*/ */
@TableField("\"WATER_OIL_VOLUME_OF_BOILER_PROPER\"") @TableField("\"WATER_OIL_VOLUME_OF_BOILER_PROPER\"")
private String waterOilVolumeOfBoilerProper; private String waterOilVolumeOfBoilerProper;
/** /**
* *
*/ */
@TableField("\"HYDRAULIC_TEST_MEDIUM_PRESSURE_OF_PACKAGED_BOILER_BODY\"") @TableField("\"HYDRAULIC_TEST_MEDIUM_PRESSURE_OF_PACKAGED_BOILER_BODY\"")
private String hydraulicTestMediumPressureOfPackagedBoilerBody; private String hydraulicTestMediumPressureOfPackagedBoilerBody;
/** /**
* *
*/ */
@TableField("\"INLET_OUTLET_TEMPERATURE_OF_REHEATER\"") @TableField("\"INLET_OUTLET_TEMPERATURE_OF_REHEATER\"")
private String inletOutletTemperatureOfReheater; private String inletOutletTemperatureOfReheater;
/** /**
* *
*/ */
@TableField("\"REHEATER_INLET_OUTLET_PRESSURE\"") @TableField("\"REHEATER_INLET_OUTLET_PRESSURE\"")
private String reheaterInletOutletPressure; private String reheaterInletOutletPressure;
/** /**
* *
*/ */
@TableField("\"REHEAT_STEAM_FLOW\"") @TableField("\"REHEAT_STEAM_FLOW\"")
private String reheatSteamFlow; private String reheatSteamFlow;
/** /**
* *
*/ */
@TableField("\"GL_AIRTIGHT_TEST\"") @TableField("\"GL_AIRTIGHT_TEST\"")
private String glAirtightTest; private String glAirtightTest;
/** /**
* *
*/ */
@TableField("\"FUEL_TYPE\"") @TableField("\"FUEL_TYPE\"")
private String fuelType; private String fuelType;
/** /**
* *
*/ */
@TableField("\"NAME_OF_PRESSURE_PARTS\"") @TableField("\"NAME_OF_PRESSURE_PARTS\"")
private String nameOfPressureParts; private String nameOfPressureParts;
/** /**
* *
*/ */
@TableField("\"MATERIAL_OF_PRESSURE_PARTS\"") @TableField("\"MATERIAL_OF_PRESSURE_PARTS\"")
private String materialOfPressureParts; private String materialOfPressureParts;
/** /**
* *
*/ */
@TableField("\"WALL_THICKNESS_OF_PRESSURE_PARTS\"") @TableField("\"WALL_THICKNESS_OF_PRESSURE_PARTS\"")
private String wallThicknessOfPressureParts; private String wallThicknessOfPressureParts;
/** /**
* *
*/ */
@TableField("\"NON_DESTRUCTIVE_TESTING_METHODS_FOR_PRESSURE_PARTS\"") @TableField("\"NON_DESTRUCTIVE_TESTING_METHODS_FOR_PRESSURE_PARTS\"")
private String nonDestructiveTestingMethodsForPressureParts; private String nonDestructiveTestingMethodsForPressureParts;
/** /**
* *
*/ */
@TableField("\"PROPORTION_OF_NDT_FOR_PRESSURE_PARTS\"") @TableField("\"PROPORTION_OF_NDT_FOR_PRESSURE_PARTS\"")
private String proportionOfNdtForPressureParts; private String proportionOfNdtForPressureParts;
/** /**
* *
*/ */
@TableField("\"HEAT_TREATMENT_TEMPERATURE_OF_PRESSURE_PARTS\"") @TableField("\"HEAT_TREATMENT_TEMPERATURE_OF_PRESSURE_PARTS\"")
private String heatTreatmentTemperatureOfPressureParts; private String heatTreatmentTemperatureOfPressureParts;
/** /**
* *
*/ */
@TableField("\"HEAT_TREATMENT_TIME_OF_PRESSURE_PARTS\"") @TableField("\"HEAT_TREATMENT_TIME_OF_PRESSURE_PARTS\"")
private String heatTreatmentTimeOfPressureParts; private String heatTreatmentTimeOfPressureParts;
/** /**
* *
*/ */
@TableField("\"HYDROSTATIC_TEST_MEDIUM\"") @TableField("\"HYDROSTATIC_TEST_MEDIUM\"")
private String hydrostaticTestMedium; private String hydrostaticTestMedium;
/** /**
* *
*/ */
@TableField("\"HYDROSTATIC_TEST_PRESSURE\"") @TableField("\"HYDROSTATIC_TEST_PRESSURE\"")
private String hydrostaticTestPressure; private String hydrostaticTestPressure;
/** /**
* *
*/ */
@TableField("\"COMBUSTION_MODE\"") @TableField("\"COMBUSTION_MODE\"")
private String combustionMode; private String combustionMode;
/**
* 安装附件与有关装置
*/
@TableField(value = "\"SAFETY_ACCESSORIES_AND_RELATED_DEVICES\"")
private String safetyAccessoriesAndRelatedDevices;
} }
...@@ -27,7 +27,8 @@ ...@@ -27,7 +27,8 @@
"HEAT_TREATMENT_TIME_OF_PRESSURE_PARTS", "HEAT_TREATMENT_TIME_OF_PRESSURE_PARTS",
"HYDROSTATIC_TEST_MEDIUM", "HYDROSTATIC_TEST_MEDIUM",
"HYDROSTATIC_TEST_PRESSURE", "HYDROSTATIC_TEST_PRESSURE",
"COMBUSTION_MODE" "COMBUSTION_MODE",
"SAFETY_ACCESSORIES_AND_RELATED_DEVICES"
FROM idx_biz_jg_tech_params_boiler FROM idx_biz_jg_tech_params_boiler
WHERE RECORD = #{record} WHERE RECORD = #{record}
</select> </select>
......
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment